Service manual

Avantra 36/44 Service Manual
2-38 Functional Analysis
2.16 Humidifier Option: Warnings and
Indications
The Run and Pause screens display the humidifier enable icon when the humidifier
is enabled.
2.16.1 Humidity Low Indicator
When switching on the imagesetter, the OCP displays the humidity low icon, if
humidity is below the desired level. Once the humidity reaches the desired level,
the humidifier enabled icon replaces humidity low.
2.16.2 Water Supply Empty Alert
If the humidity level drops below the desired level and persists for more than:
15 minutes either following a power on or enabling of the humidifier
5 minutes after the humidity previously came up to the desired level
the system does three things:
A blinking low humidity icon displays
An audible alwarm sounds for 15 seconds
The software disables the humidifier option
Typically this condition means that the water bag (reservoir) is empty. To clear the
alert, you must re-enable the humidifier option.