Avantra 36/44 Service Manual
3-14 Removal and Replacement
3.7 Circulation Pump
The following describes how to remove and replace the circulation pump.
Tools Required: Flathead screwdriver, open end wrench
Remove:
1. Turn off and unplug the OLP.
2. Remove the top and side covers.
3. Drain the tank.
CAUTION: Even with the tanks drained, chemistry will remain in the
hose connections. Wear rubber gloves and have rags ready for spill-
age before proceeding to the next step.
4. Using a flathead screwdriver, loosen the hose clamps securing the two (2)
hoses to the pump. Refer to Figure 3-11. Remove both hoses.
Figure 3-11 The circulation pump.
–Hose clamps. –Circulation pump. –Power lines (electrical connection).
–Mounting plate.
5. Follow the black, white and green power wires (electrical connection) to
the terminal block and disconnect. Refer to Figure 3-11.
NOTE: Note the wire positioning for proper replacement.
2
1
3
4