Service manual
Avantra 36/44 Service Manual
4-4 Removal and Replacement
4.5 Upper Bridge Servo Motor
Tools: Phillips head screwdriver, flathead screwdriver, allen head wrench
Remove:
1. If the bridge foot is on, put the system in light mode and turn the system
off.
2. Using a phillips head screwdriver, remove the six (6) screws from the
bridge side cover on the right. Refer to Figure 4-2.
Figure 4-2 Bridge side cover.
➀–Bridge. ➁–Side cover. ➂–Electrical connector.
➃–Six side cover screws. ➄–Upper bridge servo motor.
3. Remove the electrical connector. Refer to Figure 4-2.
4. Remove the female connector from the other side of the cover. Refer to
Figure 4-3.
5. Remove the connector from the bridge up sensor to release the side cover.
Refer to Figure 4-3. Move the cover away.
6. Remove the power connectors (red on top; brown on bottom) from the
upper bridge servo motor. Refer to Figure 4-2 and 4-3.
5
2
4
3
1