Service manual

Avantra 36/44 Service Manual
3-6 Diagnostics
3.1.6 Bridge Sensor Status
The bridge sensor status displays on the terminal when a Sensor Request command
(^F) is issued from the terminal. An ā€œsā€ precedes the sensor status.
The sensor status is returned as a WORD value (two bytes). Each row of sensors (2
rows) are located in a separate byte. Row 1 (5 bits) is located in the lower byte; row
2 (5 bits) is located on the upper byte.
Sensors Located On Row 1 (Lower or Second Byte)
Sensors Located On Row 2 (Upper or First Byte)
0001 Actuator Sensor
0002 Loop Sensor
0004 Bridge Purchase Sensor
0008 Shuttle - Bridge Mode Sensor
0010 Shuttle - Cassette Mode Sensor
0100 Unused Sensor
0200 Buffer Entry Sensor
0400 Buffer Purchase Sensor
0800 Buffer at Bridge Sensor (home)
1000 Buffer at Processor Sensor