Section II: Bridge
Diagnostics 3-3
3.3 Bridge Debugger User Interface
This section describes the debugger user interface including:
• Terminal code identifiers
• Bridge states
• Error codes
• Bridge commands
• Sensor status information
• Parameters
• Bridge/buffer commands
3.1.1 Terminal Code Identifiers
3.1.2 Bridge Unlock Sequence
The bridge must be unlocked by a special sequence prior to sending any normal
bridge commands. If you attempt commands while the bridge is locked, the com-
mand echoes back preceded by an “l.” Note that the unlock sequence is automati-
cally sent to the bridge/buffer module immediately after system boot-up (if OLP is
enabled).
UNLOCK Sequence: Codes sent from DEC: c40 c20 c60
Key Sequence from Terminal: @ <SPACE> ‘
i Bridge Internal State
c Command from DEC
d Command from Debug Terminal
r Response to Command (status or acknowledge)
s Sensor Information
e Error Code
l Bridge is in a locked State
p Parameter Value (high byte, low byte)