3-2 Diagnostics
3.2 Setting Up the Debugger Port
Access the bridge debugger port software using a terminal or PC running terminal
emulation software (Procomm). The bridge/buffer module uses a 15-pin D-type
connector requiring a special adapter cable to interface to the standard serial cable.
Refer to Figure 3-1.
Figure 3-1 Avantra 36/44 Bridge Diagnostic Adapter Cable.
Use the following parts to interface from a PC to the bridge debugger port:
• 9-pin female connector (PC end) 78448-015
• 25-pin male connector (imagesetter end) 78448-016
• cable 78448-008
• bridge diagnostic adapter cable C03546-501
15 PIN MALE
D-TYPE
TX
RX
GND
6
3
2
To Buffer/Bridge Module
To Terminal Serial Cable
7
3
2
25 PIN FEMALE
D-TYPE