Service manual

Avantra 36/44 Service Manual
1-2 Installation
If the customer is setting up the optional on-line processor (OLP)/buffer as
well, the OLP electrical specifications are:
Volts: 230
Amp: 30
Rec.: NEMA L6-30P
Phases: 1, 2 or 3 phases + (neutral) + ground
Load: Maximum 7.0 kW
Environment
The system should be located in a clean, static free work area for best
operation. The system must not be placed near heating or air conditioning
equipment. The customer must provide the proper work environment as
described in
Work Space
below. Environmental specifications for the imag-
esetter include:
Oper/Temp: 65
°
to 80
°
F (18
°
to 27
°
C)
Humidity: 45 to 55%, non-condensing
For absolute accuracy 70
°
F
±
3
°
(21
°
C
±
2
°
).
Work Space
The system should be located in an area that allows enough surrounding
space to permit unrestricted air flow and service access. Approximately
three feet should be left on all sides. No overhead lights should appear
directly over the system. The system should not be located near windows
with direct sunlight. The floor where the Avantra 36/44 imagesetter is to
be placed must meet the industrial standard for weight per square foot (100
lbs/sq.ft.). Avantra's imagesetter physical specifications are:
Width: 73" (185.42 cm)
Height: 48" (121.92 cm)
Depth: 35" (88.90 cm)
Weight: 1700 lbs. (771.11 kg)