Service manual

1-1
Chapter 1:
Imagesetter
Installation
Procedures
1.1 Introduction
This chapter describes the requirements and procedures necessary for installing the
Avantra 36/44 imagesetter.
Included in this chapter are:
Customer Pre-site Checklist
Service Engineer Installation Procedure
Pre-installation Checks
Upacking the Imagesetter
Unlocking the Imagesetter
Checking the System
Customer Application Training
1.2 Customer Pre-site Checklist
The customer should use the following pre-site checklist to ensure that the intended
installation site is properly prepared to receive and install the Avantra 36/44 image-
setter.
Power Requirements
The customer must provide a separate (isolated) three wire 115/230 VAC
grounded power line. The wires can be run in conduit, but the conduit
cannot
serve as a ground. The receptacle type must be a 2 pole, 15 amp
grounded, NEMA 5-20R or equivalent. Electrical specifications for the
imagesetter are:
Volts: 115/230
Amp: 5 / 2.5
Rec: NEMA 5-20R
Power: 575 Watts
Heat Output: 1962 BTU's