Service manual
Section I: Imagesetter
Diagnostics 3-41
Carriage Motion
This item moves the carriage in the same manner as it operates during imaging. The
Carriage Motion Menu appears as follows:
Spinner On Spinner Off
Carr. Home Pos. (EEPROM) 863
Home Carriage
Carr. Slew to Position 0
Image Start 0
Image End (EOT) 0
Carr. Image to Position
Abort Carriage Movement
Video Mode 0
Resolution (Image Speed) 3600
Gate Start (Pixels) 0
Gate Length (IN.) 25
These are the carriage motion menu functions.
Feed Motor Cal
The “Feed Motor Cal” test calibrates the speed of the Supply Drive Servo Motor to
the speed of the Take-up Nip Drive Servo Motor. The media and supply cassettes
must be removed prior to performing this test. The two values will be stored in the
DEC. DSP/Plate menu in DSP address location 4 and 5.
This test should be performed after replacing either servo motor or supply/take-up
SDM boards
Imagesetter Primitives
This menu item executes imagesetter primitives usually executed by commands
sent between micro-controllers via the SPI communication link.
Menu Item Function
Spinner ON/OFF Turn the spinner on/off.
Carriage Home Position Set the carriage home position.
HOME Carriage Move the carriage to the home position.
Carriage Slew to Position Move the carriage to position at slew speed.
Image Start Set the starting position for carriage motion at image speed.
Image End (EOT) Set the ending position for carriage motion at image speed.
Carriage Image to Position Move the carriage to position at image speed.
Abort Carriage Movement Abort the carriage motion.
Video Mode Set the video mode to positive/negative.
Resolution (Image Speed) Set the imaging speed of the carriage (resolution).
Gate Start Set the start of beam on.
Gate Length Set the fast scan size of the image.