Service manual

Avantra 36/44 Service Manual
3-40 Diagnostics
Figure 3-1 Avantra sensor grid.
RowCol 00 = Humidity
RowCol 01 = Left flapper load (down) sensor
RowCol 02 = Supply jam detector
RowCol 03 = Left flapper image (up) sensor
RowCol 04 = Right side door interlock switch
RowCol 05 = Supply spindle A position sensor
RowCol 10 = Supply punch (punch) switch
RowCol 11 = Supply punch (clamp) switch
RowCol 12 = Supply spindle B position sensor
RowCol 13 = Left side door interlock switch
RowCol 14 = Spare
RowCol 15 = Suppply side media present sensor
RowCol 20 = Take-up jam detector
RowCol 21 = Take-up cassette present sensor (36”)*
RowCol 22 = Right flapper load (down) sensor*
RowCol 23 = Take-up cassette core sensor
RowCol 24 = Take-up Cassette present sensor (18”)
RowCol 25 = Right Flapper image (up) sensor
RowCol 30 = Take-up punch (punch) switch
RowCol 31 = Take-up punch (clamp) switch
RowCol 32 = Take-up cutter home
RowCol 33 = Carriage home sensor
RowCol 34 = Spare
RowCol 35 = Take-up media present sensor
RowCol 40 = Spot size changer (aperture) sensor
RowCol 41 = Polarizer home sensor
RowCol 42 = Weak lens (focus) home sensor
RowCol 43 = Spin overspeed signal feedback
RowCol 44 = Laser good signal feedback
RowCol 45 = Beam compressor home sensor
NOTE: The current state of a sensor is determined by clearing the
row and reading the column.
Row 4 40 41 42 43 44 45
Row 3 30 31 32 33 34 35
Row 2 20 21 22 23 24 25
Row 1
10 11 12 13 14 15
Row 0 00 01 02 03 04 05
Col 5
Col 4
Col 3
Col 2
Col 1
Col 0