Service manual

Avantra 36/44 Service Manual
3-36 Diagnostics
NOTE: DSP numbers 0, 1, 2, and 3 are set after executing the
Avdiag “Carriage Align” test. DSP numbers 4 and 5 are set
after executing the Avdiag “Feed Motor Cal” test.
OCP User Parameters
User Parameters
NOTE: To view the following parameters you must first down load
the OCP user parameters. Refer to Section 3.3.4.3
Selecting User Params displays a dialog box that shows the current user parameter
settings stored in the imagesetter. The parameters reside in OCP EEPROM. The soft-
ware retrieves the parameters from EEPROM when this menu selection is made.
New values can be written to the imagesetter by typing in a new value in the
appropriate parameter. Listed below is a typical customer’s User Parameters menu.
Parameter No. Value
Resolution (02) 1200
Page Size (03) 30000
Feed Default (06) 15
Unit of Meas. (07) 2
Output Device (13) 0
Supp. Cass. No (15) 1
Video Mode (17) 0
Media Usage (24) 5
Fast Scan Coord (25) 0
Slow Scan Coord (26) 0
XY Coord Opt (27) 0
Interpage Spac (45) 1
Feed/Cut Lead (46) 17
Jobs Imaged (48) 0
Supply Alarm (49) 309
Output Alarm (50) 500
Spindle Loaded (51) 1
Spindle Selected (52) 1
Optimiz. Mode (53) 0
Dist. Punch/Image (54) 1728
Auto Centering (58) 0
Online Time-out (59) 0
Align Cass State (97) 0
Dist. to Cutter (98) 0
Humidifier State (99) 0
OCP Volume (100) 2
Prev. Page Size (101) 0
Spind. Punch Opt. (102) 0
Viewing Angle (103) 14
Lifemedia Limit (105) 0
Small Feed Error (106) 0
Large Feed Error (107) 0