Service manual
Avantra 36/44 Service Manual
3-32 Diagnostics
* System dependent
Special Notes
1. The “S-Feed Speed” value may be different between standard Avantras and
Avantra “S” systems. Check Machine Parameters of the software revision
that is loaded into your system.
Variable
Media
Parameter
Film
(3-5)
Narr
Film
(3-5)
Med
Film
(3-5)
Wide
Film
(6-8)
Narr
Film
(6-8)
Med
Film
(6-8)
Wide
Film
(9-12)
Narr
Film
(9-12)
Wide
Paper
Narr
Paper
Wide
S-Feed Current 24 24 24 40 46 50 50 32 2 34
T-Compress Curr 24 24 24 36 40 60 60 28 24 24
T-Compress Speed 6 6 6 12 12 12 12 6 6 6
Midpoints (.01”) M4..............2400 M8...............2400 M12............2600 MP.............3050
W4.............3000 W8..............3000
Parameter Parameter Parameter Parameter
S-Feed Speed * TU Align Cur-N 128 TU Start Dly 0 PP-PushDist 33
S-Hold Speed 12 TU Wind Cur-N 75 TU Dly/Dist 100 PP-PushCurr 24
S-Hold Curr 25 TU Align Cur -W 128 TU Beg. IRge 112 PP-PushSpd 8
S-Rew Curr 255 TU Wind Cur-W 75 TU End IRge 204 PP-HPul Len 5
S-A/B Offset * TU Align Cur -Pl 128 ImgFd Cst Dly 10 PP-HPul Spd % 1
S/TU Delay 0 TU Wind Cur-Pl 75 Rev SupSvoCur 60 P-LPul Len 2
Media Setl Dly 40 TU Align Spd-N 60 Rv-TUSvoCurPap 30 P-LPul Spd % 3
Nip Delay 30 TU Wind Spd-N 65 Rv-TUSvoF/Pl 80 PP-PreRmpDly 1
Out of Media Ctl 450 TU Wind Spd-Pl 65 Extra Fd Len 70 VacOn Tim 30
Spdl Fwd Asst 50 Nips Op Ely. Time 1 S Cmp Curr Rtio 50 VacOff Time 10
FeedHold Curr 12 FeedHold Spd 8 TU Ramp St 180 TU Ramp St-P 160
TU Svo FuSp 90 USvo FuSp-P 85