Service manual
Section I: Imagesetter
Diagnostics 3-27
ALIGN MENU
Imagesetter Configuration
This menu item displays a window containing the currently set options and
changes any option setting and saves the configuration to the imagesetter. This set-
ting stores as a machine parameter in DEC EEPROM.
The currently settable options are:
Machine Type............Set Machine ID to all the different Avantra engines
Options Function
Head Punches Punches at the takeup cassette side of the media path
Tail Punches Punches at the supply side of the media path
Dual Spindles Two media supply sources
Media Thickness Allows for different thickness media to be used
Media Width Allows for media widths of .01 increments
Bridge-Up Sensor Enable/disable Bridge-up Sensor (AV44)
30K Spinner (future option)
Multiple Spot Flag SGM with four aperture flags (all AV44)
APIS Buffer Avantra with APIS Buffer option (AV44)
Extra Supply Feed An additional 4 inch feed during new media loads
Carr Home @ Ea Image Home carriage after each image (AV44)
Wrong Read Mode Type of Wrong Reading (Fast Scan or Slow Scan)
Humidifier Enable humidifier icon in configuration screen
Bridge/Buffer Board Enable for OLP systems
Leakless Vacuum Enable for systems with improved vacuum
Widened Media Width Enable for Avantra 30 with 13.3" media
Real-Time Clock Enable for systems that support real-time clock
12 Mil Plate Rewind