Service manual
Section I: Imagesetter
Diagnostics 3-13
3.2.5 Boot Error Codes
Table 3-1 lists the Avantra boot error codes.
Table 3-1 Boot error codes.
Error Code Description
135 Spinner Overspeed error
136 Door Open during Boot
137 OCP Hardware Handshake error
138 DEC flash ROM is blank
139 Cannot switch K-4 to master mode
140 DSP hardware handshake error
141 Cannot Set DACs to zero
142 Carriage DAC failed to go low (-4 volts)
143 DAC failed to go high (+4 volts)
144 Supply current DAC failed
145 Take-up current DAC failed
146 Spinner DAC failed
147 Take-up servo DAC failed
148 Supply servo DAC failed
149 Spinner did not lock
150 Offgate register failed
151 Ongate register failed
152 Vacuum register failed
153 Diag to OCP handshake failed
154 Diag to DSP handshake failed
155 Diag to DEC K-4 handshake failed
156 DEC K-4 offgate register failed
157 DEC K-4 ongate register failed
158 DEC K-4 vacuum register failed
159 DEC K-4 to DSP handshake failed
160 Carriage Sensor/Cable not connected
161 Carriage not in idle state
162 Cannot command DSP to zero-out carriage
position loop
163 Cannot command DSP to move carriage
164 Cannot command DSP to stop carriage
165 No carriage encoder pulses
166 Missing (not enough) encoder pulses