Installation guide
Stopping the exhibitSyncNotifier service
(Topic number: 58418)
Once a site is migrated to IMPAX 6.5.3, the exhibitSynchNotifier service is no longer supported.
You must therefore stop the exhibitSyncNotifier service, if it is still running on an upgraded station.
To stop the exhibitSyncNotifier service
1. On the AS300 server, navigate to C:\mvf\sync\bin.
2.
Double-click stopExhbitSyncNotifier.bat.
The exhibitSyncNotifier service is stopped.
You can also uninstall Data Currency.
Uninstalling Data Currency from an AS300 server
(Topic number: 58421)
After the WEB1000 Data Currency service is stopped, you can uninstall it. To do so, you must be
logged into Windows as an administrator-level user.
To uninstall Data Currency from an AS300 server
1.
Open the Windows Administrative Tools and select Services.
2.
Locate the Exhibit PACS Synchronization Notifier service and stop it.
3. Exit from the Administrative Tools.
4. In Windows Explorer, navigate to the C:\mvf\sync\bin directory.
5.
Run removeSystemDate.bat.
6.
Run removeJobQueue.bat.
7.
Run removeSync.bat.
8. Open Control Panel.
9.
Select Add or Remove Programs.
10.
Under Currently installed programs, select PACS Synchronization version
where version is the version of the software.
11.
Click Change/Remove.
12.
When prompted to confirm the removal, click Yes.
Data Currency is uninstalled.
AS300 Upgrade Guide—IMPAX 5.2 or 5.3 to IMPAX 6.5.3 71
Agfa Company Confidential—Subject to Non-Disclosure Obligation