Installation guide

We recommend that you back up the registry before you change it, so that you can back out
the changes, if necessary.
To synchronize Windows servers to an internal time source
1.
To open Registry Editor, select Start > Run, type regedit, and click OK.
2. To specify if the local machine is a local time server, in the
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Config\AnnounceFlags
subkey, change REG_DWORD to A.
3. Exit the Registry Editor.
4.
To stop and restart the Windows Time server, at a command prompt, type net stop w32time
&& net start w32time.
It may take some time for this to take effect.
Note:
Do not configure the PDC master to synchronize with itself.
Synchronizing with a time server when the IMPAX computer is not
a member of a domain
(Topic number: 58572)
To ensure that image data streaming operates correctly when the IMPAX computer is not a member
of a domain, use the synchronization feature built into the operating system.
To synchronize with a time server when the IMPAX computer is not a member of a domain
1. Open Control Panel.
2.
Select Date and Time.
3.
Switch to the Server Internet Time tab.
4. In the list, type or select the time server to synchronize with.
Synchronizing with a time server when the IMPAX computer is a
member of a domain
(Topic number: 58569)
To ensure that image data streaming operates correctly when the IMPAX computer is a member of
a domain, use the synchronization feature built into the operating system.
To synchronize with a time server when the IMPAX computer is a member of a domain
1. Open a command prompt.
AS300 Upgrade Guide—IMPAX 5.2 or 5.3 to IMPAX 6.5.3 58
Agfa Company Confidential—Subject to Non-Disclosure Obligation