Installation guide
To restart antivirus software
1. On a Windows server where scanning was stopped, launch the antivirus software.
2. Start the scan operation according to the vendor’s instructions.
Testing the installed software
(Topic number: 61185)
14.
After installing the new version of IMPAX, perform certain tests to verify that the installation was
successful.
To test the installed software
1. On the IMPAX Database Server, run the Administration Tools and ensure that you can log in
using the administration password.
2.
On the Application Server, open a web browser and connect to http://localhost. Ensure that
the “Welcome to IMPAX” page is displayed.
3. Run the IMPAX Client and ensure that you can log in using the administration password.
Restarting an archive queue
(Topic number: 32239)
15.
Restart the Archive queue or queues that were halted before the IMPAX upgrade.
To restart an archive queue
1. Log into the IMPAX 6.5.3 Administration Tools.
2.
On the Daily tab, select Job Manager.
3. In the queue list, select the archive queue.
4.
Click Restart.
Restarting Connectivity Manager queues
(Topic number: 67610)
16.
If Connectivity Manager is currently deployed, and you have stopped any queues, use the Queue
Manager to restart them. Once the queue is restarted, messages sitting in them are processed.
To restart Connectivity Manager queues
1.
In the Connectivity Manager Service Tools, click Queue Manager.
AS300 Upgrade and DAA Consolidation Guide—IMPAX 6.2 or 6.3 to IMPAX 6.5.3 41
Agfa Company Confidential—Subject to Non-Disclosure Obligation