Installation guide
3. Type the following:
build-impax-mig-schema.bat sa sa mvf
4.
At the Do you want to proceed? prompt, type y.
The pre-migration database schema and data are created.
Setting up a connection to a previous-version
AS300 database
(Topic number: 6627)
4.
Use this procedure to connect the Application Server to an IMPAX 4.5, 5.2, or 5.3 AS300 Database
Server.
To set up a connection to a previous-version AS300 database
1. To use the 32-bit version of the ODBC Data Sources tool, run
C:\Windows\SysWOW64\odbcad32.exe.
Do not select Data Sources (ODBC) through the Windows Administrative Tools as this runs
the 64-bit version of the tool.
2.
Switch to the System DSN tab.
3.
Click Add.
4.
In the Create New Data Source dialog, select SQL Server from the list. Click Finish.
5. In the Name field, type the appropriate value:
For IMPAX 4.5 upgrades, use mvf_45.
For IMPAX 5.2 upgrades, use mvf_52.
For IMPAX 5.3 upgrades, use mvf_53.
The mvf name is already being used by the temporary IMPAX 6.5.3 AS300 server.
6.
In the Description field, type mvf (lowercase).
7.
In the Server field, type or select the name of the 4.5, 5.2, or 5.3 AS300 server. Click Next.
8.
Set the authentication according to the authentication used at the site (Windows NT or SQL
Server).
9.
If necessary, select the Connect to SQL Server checkbox and supply a Login ID and Password.
10.
If necessary, change the network library by clicking Client Configuration. Under Network
libraries, select the protocol used to communicate with the SQL server at your site: either
TCP/IP (the default) or Named Pipes. Click OK.
11.
Click Next.
12.
Change the default database to mvf (lowercase). Click Next.
13.
Click Finish. Click OK.
AS300 Upgrade and DAA Consolidation Guide—IMPAX 5.2 or 5.3 to IMPAX 6.5.3 29
Agfa Company Confidential—Subject to Non-Disclosure Obligation