Specifications

Global Services North America
Wilmington MA 01887
Site Readiness Check List
Information to Check
Yes
No
Lateral fork movement capability. Proper lifting rating? (Pg.4)
Forklift
Length of forks should be 60 inches (152.4cm) minimum
Loading Dock If the customer does not have a loading dock, then the freight truck
delivering the Anapurna will need a lift gate to lower the crate to the ground
along with the forklift
3 - 5 HP, 60 - 80 gallon or better Capacity Compressor?
24/7 Operation is required. The compressors regulator should be set to
105 - 110 PSI for trip OFF and to 85 PSI to trip ON. Printer air volume is:
.28 CFM
See page 6
Air filtration for moisture and particles?
Compressed Air
Supply
Air regulator for the Printer?
Humidity
Range 35% to 75% RH (non-condensing) Ideal 40% ?
Air
Temperature
Not to exceed 126º F or 52 ºC
Room
Temperature
Range 68° F to 80° F (20 – 26.6° C) Ideal 72° F (22° C) ?
Room air exchange should be 10 times per hour ? page 14
RIP Computer
Specs Met?
Refer to page 7 for details. Windows Vista operating system can not be
used.
208 V, Single Phase, 60 Hz
40 Amp breaker circuit?
Dedicated Circuit?
Line voltage for
the printer
A Buck/Boost transformer maybe required to bring the voltage up to 230 -
240 VAC Range.
See page 9.
Floor should be concrete, flat and stable, No Carpet.
Floor Area
Load per foot on the floor:
156 lbs/ft² (70 kg/m²). Floor Space: Depth 16.4
feet (5m) x Width 18 feet (5.5m). For 8 – 12 foot boards optional tables are
required. Floor Space:
Depth 24.6 feet (7.5m) x Width 18 feet (5.5m)
Check for clearance (uncrated). No less than 7 foot or 213 cm high. (Pg.4)
Check doorways for clearance (height, width)
Ceiling Height
Check path from loading dock to installation location
Is there room for the removal and replacement of parts for servicing? (Pg. 5)
System
Orientation
Can all printer doors open fully?
Head Wipes Customer informed of proper heads wipes required? (Pg 14)
Questions? Contact 800-879-2432 and ask for an Anapurna Specialist
12