10 Clean the print head resistor line.
Gently pass over the resistor line a few times with a lint free cloth, slightly moistened
with Isopropyl alcohol or Ethanol.
Do this only in one direction, i.e. from left to right, without lifting the cloth.
11 Close the print head unit, the hold-down bracket and finally the top cover.
After you have cleaned the print head resistor line and you have closed the top cover,
you will return automatically to the Select calibration menu (see step 3).
12 Press the Escape key to return to the key-operator main menu.
Note: Do not apply any pressure on the print head because this pressure
may cause damage on the interconnections underneath the print head.
Note: If residue dust is present as part of the cleaning procedure it will
disappear after a few prints.