User's Manual Part 2
Table Of Contents
- Table of contents
- Introducing the Drystar5300
- Basic operation (Operator mode)
- Advanced operation (Key-operator mode)
- Overview of key-operator functions
- Viewing printer information
- Accessing the Show settings menu
- Viewing general information
- Viewing input tray information
- Viewing network (DICOM) information
- Viewing general image quality information
- Viewing default densitometer information
- Viewing image quality information of a modality
- Viewing installed data-sets information
- Viewing logical printers information
- Changing the configuration settings
- Printing images
- Saving the configuration settings
- Restoring the configuration settings
- Maintaining optimal image quality
- Service actions
- Quality control procedure
- Installation operations
- Controlling the Drystar5300 via a remote PC (with browser)
- System description
- Preventive maintenance
- Troubleshooting
- Equipment information sheet
- Drystar media density response data
- Quality Control Charts
- Index
88
2920B EN 20031206
" If you do not want to use the default settings, press the Down key,
followed by the Confirm key to choose ‘Select other’. The Drystar 5300
will continue with the ‘Select for Modality’ screen, allowing you to change
the Look-up table, the Interpolation and the MaxD values manually, as
explained in the following paragraphs.
Selecting another look-up table
1
Perform steps 1 to 3 of the ‘Changing Image quality settings for a modality’
procedure on page 87 to select the modality and choose ‘Select other’.
The ‘Select for Modality’ screen is displayed:
2 In the ‘Select for Modality’ screen, press the Confirm key to select ‘Look-up
table’.
The ‘Look-up table’ screen is displayed:
3 Press the up/down key to select the desired look-up table.
4 Press the Confirm key to store the data, or the Escape key to quit the
procedure without any changes.
$ In case Kanamori-like (100) is selected, you can change the Kanamori-like
value (the range is: 75-200, the default value = 100).
An additional screen for the Kanamori-like value is displayed:
Enter the Kanamori-like value by means of the arrow keys. Refer to ‘Data entry’ on
page 27. Press the Confirm key to store the data, or the Escape key to quit the
procedure without any changes.
CS
Select for
Modality16char:
1 Look-up table
2 Interpolation
3MaxD
CS
Select for
Modality16char:
1 Linear
2 Kanamori
3 Kanamori-like (100)
CS
Select for
Modality16char:
Kanamori-like value:
100