SYSTEM HARDWARE OVERVIEW
ETHERNET INTERFACE
An optional Cat 6 Ethernet interface is provided on product connector 2. The 350 radar requires it be connected
to a network and be able to obtain an IP address through a DHCP server.
A Cat 6 interface cable is not provided for use with the product, but should it be fitted, it should be of the type:
Overall braid screened, shielded twisted pair (S/FTP). This is to ensure EMC compliance.
Connector Details:
Product Connector: RJ45 Bulkhead Connector - Amphenol P/No RCP-5SPFFH-TCU7001
The following connectors are supplied with the 350 radar:
Option 1 – Amphenol RCP-00AMMA-SLM7001
Connector needs to be assembled prior to the fitting
of the RJ45 connector. Recommended cable OD
range = 4.5mm to 6.5mm
Option 2 – Amphenol RCP-00BMMS-SLM7001 (Field installable)
Prior assembled RJ45 Ethernet cable can be fitted
into this housing (RJ45 connectors fit through and
into this connector). Recommended cable OD
range = 5.0mm to 6.5mm.
NOTE:
a) The RJ45 at the 350 end MUST NOT have any sort of boot fitted - to enable it to fit correctly into this connector.
b) The Ethernet braid shield of the external cable, at the customer equipment end, must be connected to a good
ground earth point in order to comply with EMC requirements.
c) Whichever Ethernet connector is used, the snap on ferrite (CP-07-015) which is supplied with the 350
must be fitted to the 350 end of the Ethernet cable (with 2 turns) as shown below in order to comply with EMC
requirements.
CP-07-015 Positioning
POSITION SNAP
ON FERRITE 20MM
(-0MM/+3MM) FROM THE
CABLE END TO ENSURE
COMPLIANCE WITH EMC
REQUIREMENTS
2 TURNS APPLIED TO THE
CABLE AS SHOWN
NOTE THE CONNECTOR
MAY DIFFER BUT THE 70MM
(-0MM / 3MM) DISTANCE
IS REQUIRED AS ARE THE
2 TURNS