User's Manual
27
MESSAGE FORMATS
RADAR ERROR MESSAGES
Error Number table
Error Number Description Response Actions
01 Corruption of User
Configuration Data
Radar will attempt to
restore Factory Default
Data configuration set
User will need to reset individual
configuration variances from default set
02 Corruption of
Factory Default Data
Configuration set
Radar operation will
automatically shut down as
operation to specification
cannot be assured
Return radar to AGD for repair and/or
recalibration
03 Corruption
of Critical
Configuration Data
Radar operation will
automatically shut
down as operation to
specification is not
possible
Return radar to AGD for repair and/or
recalibration
04 Internal
communication
error.
Communication
between radar
processors has
failed.
Radar operation will
automatically shut down
Return radar to AGD for repair and/or
calibration
05 General error Radar has internal code
tags to indicate resource
usage and levels of
processing load
User should ignore if infrequent.
Repeated occurrence suggests radar
nearing specification limits and should be
shut down by the user. It should be noted
that repeated occurrence of this message
may be owing to the specific site at which
it is deployed and or the associated
targets making the radar work close to its
operational processing limits.
06 Sampling
Frequency Error
The radar will continue to
operate.
If the sampling Frequency Error is
persistent ie more than one message
every 10 secs, then the radar operation
to specification cannot be assured and
should be shut down by the host system.
The radar should be returned to AGD for