AIR SUPPLY
Kitchen or Internal Space Air Supply
The appliance can only be installed in a room which meets ventilation regulations in force but in
any event the room must have a permanent vent of minimum free air area of 36cm
2
.
INSTALLATION PIPES
Installation Pipes should be fitted in accordance with current Gas Regulations. Pipework from
the meter/tank to the cooker must be of adequate size, cooker connection size of 15mm Dia. On
completion test the gas installation for soundness and purge in accordance with the above
standard.
ELECTRICAL
A 3 Amp 230V~50Hz fused electrical supply is required adjacent to the appliance. External wiring
to the fan unit must be installed using a 3 core heat resisting silicone sheathed cable and in
accordance with the current Wiring Regulations and any local regulations which apply. The
wiring method should be completed as indicated:
The method of connection to the mains electricity supply must facilitate complete electrical
isolation of the appliance, preferably by the use of an unswitched shuttered socket outlet in
conjunction with a fused three pin plug. Alternatively, a fused double pole switch, having a
contact separation of at least 3mm in both poles, serving only the appliance may be used.