Technical data
CAUTION: ENSURE THAT COOKER IS ISOLATED FROM ELECTRIC SUPPLY
The cooker can be installed with an approved flexible connection. Supply piping should not be
less than 3/8 I/D Flexiline. Connection is made to the 1/2” NPT female threaded elbow located
just below the hotplate level on the near left hand side of the cooker.
The gas flexiline connector must be fitted in the shaded area indicated in Fig. 10. Take into
account that it must be possible to pull the cooker forward sufficiently and that no strain occurs
on pipework. Ensure flexiline is not trapped between electrics cover and rear wall. Ensure
flexiline is routed within shaded area, and away from the shielded vent.
NOTE: AN EASILY ACCESSIBLE MANUAL SHUT GAS VALVE MUST BE FITTED BEFORE
THE METAL FLEX GAS LINE.
NOTE: Use soapy water solution on new gas connections to ensure there are no gas leaks.
18
CONNECTING TO GAS - COMPANION
Fig. 10
DESN 511751
480mm (18
7/8
”)
390mm (15
1/4
”)
200mm (7
7/8
”)
460mm (18”)
573mm (22
1/2
”)
558mm (22”)
279mm (11”)
TERMINAL
BLOCK
COVER