COMMISSIONING (CONTINUED)
7. Check burner pressure as follows:-
Repeat instruction 6 on completely cold cooker with the pressure gauge fitted to the burner
pressure test nipple (E). (See Fig. 6). Check that the burner pressure correctly
corresponds with the table marked ‘TECHNICAL DATA ‘, (page 7).
NOTE: IF FOR ANY REASON A GAS RATE CHECK IS REQUIRED. TURN OFF ALL OTHER
APPLIANCES USING GAS AND USING THE GAS METER TEST DIAL AND STOPWATCH.
CHECK THAT THE MAXIMUM GAS INPUT TO THE APPLIANCE IS AS INDICATED ON THE
DATA PLATE.
Once the correct setting has been confirmed, the heat control will operate automatically to
maintain the cooker at full temperature.
NOTE: REMEMBER TO NOTE THE SETTING POSITION IF TURNING OFF THE COOKER.
INSTRUCTIONS
Hand these and the operating instructions to the User for retention and instruct in the safe
operation of the appliance.
Finally advise the User that, for continued efficient and safe operation of the appliance it is
important that adequate servicing is carried out at regular intervals recommended by the AGA
Distributor or local Gas Region.