Technical data

This is a class 2, type X appliance.
The side wall above the hob shall be greater than 60mm from the cooker, only when adjacent
to combustible material.
Surfaces over the top of the cooker must not be closer than 650mm.
The vent slots in the back of the top plate (or shroud) must not be obstructed.
If possible, any hot water pipes from the AGA Cooker should be routed away from the Module.
The extension channel section at the rear of each side plate may be removed, if required, to
clear hot water or flue pipes with the following provisos:-
If hot water pipes pass at the rear, they should be lagged and a 50mm air gap provided
on the LH side of the cooker.
Note: It is advisable that the supply cable is routed away from any hot surfaces i.e. hot
water/flue pipes.
In the interest of safety, due consideration must be given to the protection of the electric
cable to the module.
NOTE: The parent AGA may require a gas supply (See Figs. 2, 2A & 2B) and
‘INSTALLATION - Connecting to Gas’ section.
.
6
LOCATION