Technical data
Electrical connections are located at the back of the appliance.
Refer to Figs. 1 for wiring connection to the appliance.
Remember that an excess of cable length is required for the possible withdrawal of the cooker.
Always double check connections and ensure terminals are fully tightened and the cable is
secured to the cable clamp.
THE ISOLATOR SHOULD NOT BE POSITIONED IMMEDIATELY ABOVE THE MODULE, BUT
MUST BE SITED WITHIN 2 METRES OF THE APPLIANCE.
The Module requires a 30amp power supply fitted in conjunction with a double pole isolator with
a minimum contact clearance of 3mm and be connected to the mains with a minimum 4mm
2
cable to comply with the latest editions of the local and national wiring regulations.
ELECTRICAL CONNECTION
FIG. 1
DESN 513370
DESN 513372
5
MINIMUM 4mm
2
AND MUST COMPLY WITH THE LATEST EDITIONS OF THE LOCAL
AND NATIONAL WIRING REGULATIONS
REMOVE COVER (4
SCREWS) TO GAIN ACCESS
TO THE MAINS TERMINAL