Installation Guide
8. Using the stay rod nut adjusting tool, carefully lower the top plate adjusting nuts until the top
plate sits at the required height, making sure that the top sits level and matches the height of
the AGA TC3. (See Fig. 14). 
For servicing requirement, top plate should be removed by raising adjusters approximately 
5mm, the top plate can now be removed easily without causing damage to the enamelled 
surfaces.
When removing the top plate, the switch wiring harness should be disconnected from the 
main wiring harness at the connection point located at the front left hand side of the 
appliance, beneath the formex cover sheet.
Fig. 14 DESN 516555
9. Slide the complete handrail assembly over the left hand and centre fixing studs. Once the 
assembly has been fitted to the AGA appliance, fit the handrail endcaps (ensuring the 
handrail is evenly spaced at each end). The endcaps should be carefully pushed into place 
until they sit flush with the outside face of each bracket. (A light smear of lubricant, such as 
washing up liquid can be applied to the end cap rubber ‘O’ rings to aid fitment of endcaps into
handrail if required).
The handrail can now be locked into place using the grub screws on the underside of the 
handrail brackets.
Finally fit plinth facia onto magnets positioned on plinth, ensuring the facia sits squarely and
centrally.
.
16