ELECTRICAL CONNECTION
• Remove the cover from the Field Wiring Compartment with a 
Phillips screwdriver.
• Feed the Power Supply Cable through the electrical knockout. 
Connect the Power Supply Cable to the rangehood cable. 
Attach the Power Supply Cable grounding lead to the green 
screw provided. Attach the White lead of the power supply 
to the White lead of the rangehood with a twist-on type 
wire connector. Attach the Black lead of the power supply 
to the Black lead of the rangehood with a twist on type wire 
connector.
• Replace the cover.
CHIMNEY ASSEMBLY
Upper Exhaust Chimney
• Slightly widen the two 
sides of the upper 
chimney and hook them 
behind the brackets 
7.2.1, making sure that 
they are well seated.
• Secure the sides to the 
brackets using the 4 
screws 12c supplied.
Lower Exhaust Chimney
• Slightly widen the two sides of the chimney and hook 
them between the upper chimney and the wall, making 
sure that they are well seated.
• Fix the lower part laterally to the hood body using the 2 
screws 12c supplied.
Dimensions 
and Parts
Ref Qty
Product Components
1 1
Hood Body, complete with: Controls, Light, Blower,Filters
2 1
1 Telescopic Chimney comprising:
2.1 1
Upper Section
2.2 1
Lower Section
10 1
Damper
15 1
Air Outlet Connection
Ref Qty
Installation Components
7.2.1 2
Upper Chimney Section Fixing Brackets
11 6
Wall Plugs (if supplied)
12a 6
Screws 3/16" x 1 3/4"
12c 6
Screws 1/8" x 3/8"
Qty
Documentation
1
Instruction Manual
Specifi cations are subject to change without notice. Visit www.aga-ranges.com for the most up-to-date information.
EN
1
12
ELECTRICAL CONNECTION 
• Remove the cover from the Field Wiring Com-
partment with a Phillips screwdriver. 
•  Feed the Power Supply Cable through the electrical 
knockout. Connect the Power Supply Cable to the 
rangehood cable. Attach the Power Supply Cable 
grounding lead to the green screw provided. Attach 
the White lead of the power supply to the White 
lead of the rangehood with a twist-on type wire 
connector. Attach the Black lead of the power sup-
ply to the Black lead of the rangehood with a twist-
on type wire connector. 
•  Replace the cover.
For the 36" 
Knockout is located in the junction box on the lef
t
side of the hood facing the front approx. 9-3/8" from 
the left to the right and 3-3/8" up from the bottom o
f
the hood.
For the 44" model 
Knockout is located in the junction box on the Left
side of the hood facing the front approx. 13-3/8" from 
the left to the right and 3-3/8" up from the bottom o
f
hood. 
Chimney assembly 
Upper exhaust Chimney 
•  Slightly widen the two sides of the upper chimney 
and hook them behind the brackets 7.2.1, making 
sure that they are well seated. 
•  Secure the sides to the brackets using the 4 screws 
12c supplied. 
Lower exhaust Chimney 
•  Slightly widen the two sides of the chimney and 
hook them between the upper chimney and the 
wall, making sure that they are well seated. 
•  Fix the lower part laterally to the hood body using 
the 2 screws 12c supplied. 