User and Care Manual
47
16. Technical Data
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity. Remove the drawer
(see Overview > Storage for details).
COUNTRY OF DESTINATION: USA, Canada.
Connections
Electric 240 V 60 Hz
Gas ½” NPT at rear right-hand side
Dimensions
Overall height minimum 3515/16” (91cm) maximum 367/8” (93.7cm)
Overall width 35½” (90cm); see ‘Positioning of Range’.
Overall depth 285/8” (720 mm)
Minimum space for cooktop 31½” (800 mm)
Ratings
Oven Left-hand Oven Right-hand Oven Broiler
Fan element 2.5 kW 2.5 kW 2.3 / 1.15 kW
Top element 1.2 kW - -
Browning element 1.15 kW - -
Bottom element 1.0 kW - -
Gas Top
Bypass
Screw*
Natural Gas 4” WC Propane Gas 10” WC
Input Orice Input Orice
Centre burners 49 17,000 btu/hr 205 17,000 btu/hr 118
Larger burners 38 12,000 btu/hr 150 12,000 btu/hr 99
Right-hand front burner 31 6,000 btu/hr 112 6,000 btu/hr 68
* The valves in this range are tted with adjustable bypass screws. The range is supplied with the bypass screws set for Natural
gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Data
Ovens
Left-hand
Multi-function
Right-hand
Convection
Maximum total electric load 240 V
2.5 kW 2.5 kW
Usable volume (cubic feet) 2.77 2.79
Maximum total electric load 240 V (including oven fans, lights, etc.): = 7.4 kW, 30.8 A.
NOTE: The maximum input at any time is given as both ovens fanned and broiler, plus cooling fan.
ArtNo280-0090 Drawer Cavity & Badges