User and Care Manual

44
INSTALLATION
Check the appliance is electrically safe when you have nished.
5. Attach the ground strap to the neutral and earth
terminal post supplied on the cooker back plate (Fig.
13.9). Tighten the xings to 3 - 4 Nm (2.20 - 2.95 ft lb).
6. Connect the power cord wire to the terminal block and
tighten to 3 - 4 Nm (2.20 - 2.95 ft lb).
7. Tighten the strain relief making sure the wires of the
supply cord are installed correctly (Fig. 13.7).
8. Replace the electrical connection cover.
9. Electrically test the applliance as required by local
electrical codes.
3-Wire Conduit Installation
1. Disconnect the supplied power cord from the terminal
block, ground and neutral posts. Remove the strain
relief clamp from the power cord and strain relief clamp
from the terminal box mounting plate (Fig. 13.9).
2. The range is shipped with reducer plates to give a 11/8’
diameter opening for conduit connection. Locate the
reducer plates (Fig. 13.4) in the conversion kit and x
them to either side of the thermal box mounting plate
(Fig. 13.5).
3. Attach a squeeze connector (not supplied) to your
conduit (Fig. 13.10). Insert the conduit through the
terminal box mounting plate (reducer plate tted).
Allow enough cable to connect the wires to the terminal
block, earth and neutral posts (Fig. 13.9).
4. Attach the ground strap between the earth and neutral
posts located as supplied on the cooker back plate (Fig.
13.9). Tighten the clamps to 3 - 4 Nm (2.20 - 2.95 ft lb).
5. NOTE: Make sure the cord wires are correctly
terminated (Please refer to local electrical codes) and
assemble correctly onto the terminal block (Fig. 13.9).
Retighten the security clamps to 3 - 4 Nm (2.20 - 2.95 ft
lb).
6. Secure the squeeze connector in place in the terminal
box mounting plates (Fig. 13.10).
7. Replace the electrical connection cover.
8. Electrically test the appliance as required by local
electrical codes.
ArtNo.280-0043 3-Wire conduit fitting
Black
Red
White
Terminal ClampTerminal Block
Red
White
Terminal Box Mounting Plate
Neutral Post
Ground Strip
Strain Relief
Power Cord
Black
Earth Post
Fig. 13.9