User and Care Manual
43
INSTALLATION
Check the appliance is electrically safe when you have nished.
Connecting if the Supplied Cord and
Plug is not Suitable
To remove the electrical connection cover (Fig. 13.1), remove
the 4 screws (Fig. 13.2).
4-Wire Conduit Installation
1. Disconnect the supplied power cord from the terminal
block, ground and neutral posts. Remove the strain
relief clamp from the power cord and strain relief clamp
from the terminal box mounting plate (Fig. 13.3).
2. The range is shipped with reducer plates to give a 11/8’’
diameter opening for conduit connection. Locate the
reducer plates (Fig. 13.4) in the conversion kit and x
them to either side of the thermal box mounting plate
(Fig. 13.5).
3. Attach a squeeze connector (not supplied) to your
conduit (Fig. 13.6). Insert the conduit through the
terminal box mounting plate (reducer plate tted).
Allow enough cable to connect the wires to the terminal
block, earth and neutral posts (Fig. 13.6).
NOTE: DO NOT install the conduit without a squeeze
connector.
4. Attach the wires to the terminal block, ground and
neutral post (Fig. 13.3).
5. NOTE: Make sure the cord wires are correctly
terminated (please refer to local electrical codes) and
are assembled correctly into the terminal block, earth
and neutral post. Retighten the securing xings to 3 - 4
Nm (2.20 - 2.95 ft lb).
6. Secure the squeeze connector in place in the terminal
box mounting plate.
7. Replace the electrical connection cover.
8. Electrically test the appliance as required by local
electrical codes.
Installing a 3-Wire Power Cord
1. Disconnect the supplied power cord (4 wire) from the
terminal block, ground and neutral posts. Remove the
strain relief clamp from the power cord and strain relief
clamp from the terminal box mounting plate (Fig. 13.3).
2. NOTE: DO NOT install the new 3 wire power cord
without a suitable strain relief – use the clamp supplied
with the range, if this is suitable, or the one supplied
with the 3 wire cord.
3. Install the new strain relief device into the terminal box
housing plate by removing the two clamping screws,
feeding the two halves (ears rst) through the hole in
the mounting plate and loosely replacing the screws
(Fig. 13.7). Insert the power cord through the strain
relief device but DO NOT tighten the device yet (Fig.
13.7).
4. A ground strap is supplied in the conversion pack
(Fig. 13.8).
Reducer plates (one either side),
tted to terminal box
mounting plate
ArtNo.280-0040 4 Wire Conduit Fitting
Red
White
Green
Black
ArtNo.280-0039 Reducer Plate
Terminal ClampTerminal Block
Red
White
Terminal Box Mounting Plate
Neutral Post
Strain Relief
Power Cord
Green
Black
Earth Post
Fig. 13.3
Fig. 13.4
ArtNo.280-0042 Ground Strap
Fig. 13.5
Fig. 13.6
Fig. 13.7
Fig. 13.8