INSTALLATION
Check the appliance is electrically safe when you have nished.
23
Location of the Range
Do not locate the range where it may be subject to strong
drafts. Any openings in the oor or wall behind the range
should be sealed. Make sure the openings around the base of
the range that supply fresh air for combustion and ventilation
are not obstructed by carpeting or woodwork.
The range may be installed in a kitchen/kitchen dining area
but NOT in a room containing a bath or shower.
Use care when moving the range on cushioned vinyl or
carpeted ooring. It is recommended the following be
followed to protect your oor:
Your range is heavy and can settle into soft oor coverings
such as cushioned vinyl or carpeting.
NOTE: This range has casters and must be installed on 1/8
in (2 mm) thick commercial grade vinyl composition oor
nishing materials or equivalent.
When the oor covering ends at the front of the range, the
area that the range will rest on should be built up to the same
level or higher than the oor covering.
This will allow the range to be moved for cleaning or
servicing. Also, make sure your oor covering will withstand
180°F. (See the Installation Safety Instructions section).
Make sure the wall coverings around your range can
withstand the heat generated (up to 200°F) by the range. See
the Installation Safety Instructions section.
You will need the following equipment to complete the
range installation satisfactorily:
• Multimeter (for electrical checks).
• Allen keys (provided in pack).
You will also need the following tools:
1. Steel tape measure
2. Cross-head screwdriver
3. Flat head screwdriver
4. Spirit level
5. 9/16 " (13 mm) wrench or socket wrench
6. 5/16 " (8 mm) socket wrench or ring wrench
Additional materials you may need:
1. Gas line shut-o valve.
2. Pipe joint sealant or UL-approved pipe thread tape with
Teon* that resists action of natural and LP gases.
3. Flexible metal appliance connector (½’’ I.D.). A 5foot
length is recommended for ease of installation
but other lengths are acceptable. Never use an old
connector when installing a new range.
4. Flare union adapter for connection to gas supply line
(¾’’ or ½’’ NPT x ½’’ I.D.).
5. Flare union adapter for connection to pressure regulator
on range (½’’ NPT x ½’’ I.D.).
6. To protect any oor covering under the range a sheet of
¼’’ thick plywood or equivalent large enough to stand
the range on.
Included Accessories:
6 interlocking cast iron grates Wok Cradle
Broiler pan & trivet Broiler pan cradle
1 drop shelf 2 at shelves
2 telescopic shelves 2 Oven Base Trays