Use and Care Guide
40
INSTALLATION 
Check the appliance is electrically safe when you have nished.
ArtNo.280-0037 Gas Connection
½“ or ¾” gas pipe
Flexible connector Adaptor
Appliance
gas inlet
Pressure regulator
AdaptorGas shut-off valve
Gas supply
OR
Connect the range to the gas supply
Shut o the main gas supply valve before disconnecting the 
old range and leave it o until the new hookup has been 
completed. Don’t forget to relight the pilot on other gas 
appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the 
use of a CSA International-certied exible metal appliance 
connector is recommended unless local codes require a hard-
piped connection.
The installation shall be made with a connector that complies 
with ANSI Z21.69.CSA 6.16 and using a quick disconnect 
device complying with ANSI Z21.41.CSA 6.9 (Fig. 14.3).
If disconnection of the restraint chain is necessary ensure the 
restraint is reconnected when the appliance is returned to its 
original installed position.
Never use an old connector when installing a new range. 
If the hard piping method is used, you must carefully align 
the pipe; the range cannot be moved after the connection is 
made.
To prevent gas leaks, put pipe joint compound on, or wrap 
pipe thread tape with Teon* around, all male (external) pipe 
threads.
A.  Install a manual gas line shut-o valve in the gas line in 
an easily accessed location outside of the range. Make 
sure everyone operating the range knows where and 
how to shut o the gas supply to the range.
B.  Install a male ½’’ are union adapter to the ½’’ NPT 
internal thread elbow at inlet of regulator. Use a backup 
wrench on the regulator tting to avoid damage. When 
installing the range from the front, remove the 90° 
elbow for easier installation.
C.  Install male ½’’ or ¾’’ are union adapter to the NPT 
internal thread of the manual shut-o valve, taking care 
to backup the shut-o valve to keep it from turning.
D.  Connect exible metal appliance connector to the 
adapter on the range. Position the range to permit 
connection at the shut-o valve.
E.  When all connections have been made, make sure 
all range controls are in the o position and turn on 
the main gas supply valve. Use a liquid leak detector 
at all joints and connections to check for leaks in the 
system. Use a product specically manufactured for 
leak detection. Leak testing of the appliance shall 
be conducted in accordance to the manufacturer’s 
instructions.
n
DO NOT use a ame to check for gas leaks.
* Teon: Registered trademark of DuPont 
Fig. 14.3 