Installation instructions
39
Read all instructions before installing or using this appliance. 
Installation Instructions
Save these instructions for future reference.
Slide the cover down to free the side tags.
Free from the bottom tag.
When refi tting the cover fi rst locate it on the 
bottom tag second locate the two side tags and 
then replace the screws.
4-Wire Conduit Installation
Disconnect the supplied power cord from 
the terminal block and ground post. Keep 
the terminal block parts; you will need them. 
Remove the strain relief clamp from the power 
cord and remove the power cord and strain relief 
clamp from the mounting bracket.
The range is shipped with reducer plates to 
give a 1 1/8’’ diameter opening for conduit 
connection. Find the reducer plates in the 
conversion kit and fi t them to the mounting 
bracket.
Fit a squeeze connector (not supplied with 
the range), to your conduit. Insert the conduit 
through the reducer plates on the mounting 
bracket. Allow enough slack to easily attach the 
wires to the terminal block.
NOTE: Do not install the conduit without a 
squeeze connector.
Fit the wires to the ground post and terminal 
block
NOTE: Make sure the wires are completely 
inserted into the terminals and secure 
connections are made.
Secure the squeeze connector in place in the 
bracket by tightening the squeeze connector 
screws.
Refi t the electrical connection cover.
Fitting a 3-Wire Power Cord
Disconnect the supplied power cord from 
the terminal block and ground post. Keep 
the terminal block parts; you will need them. 
Remove the strain relief clamp from the power 
cord and remove the power cord and strain relief 
clamp from the mounting bracket. Discard the 
strain relief clamp.
NOTE: Do not install the power cord without 
a strain relief - use the clamp supplied 
with the cord.