Dorrington - Manual
6
TECHNICAL DATA
Fuel
Nominal Output - Room
Wood
6kW
Typical refuelling intervals to
obtain nominal outputs
1 hour
Flue Gas Mass Flow 5.9 g/s
Flue Gas temp at Nominal Output 249
o
C
Gross Weight: 176 kgs
Flue Outlet: 150mm
Log Size: 330mm
Air Inlet (Optional) 120mm
This appliance has been tested in accordance with BS EN
13240
NOTE:-
A suitable chimney (minimum profile, chimney draft, tightness, etc) is a basic condition for the
proper functioning of fireplace stoves. See professional advice before installing the stove.
Chimney values are included in the attached technical sheet. A smoke shutter or a draft regulator
should be installed for chimneys with too strong a draft. Such a draft can cause problems during
operation, e.g. intensive burning, high fuel consumption and can also lead to permanent damage to
the stove.
STOVE DIMENSIONS
Fig 3