Installation Instructions

6
APPLIANCE DIMENSIONS - AGA DC5G
Fig. 2 DESN 516848 A
Range Dimensions
When surveying for a range installation the actual clearance required for the ‘body’ of the appliance should be increased by
3/8” beyond the figures quoted above. This allows safe margin to take into account the natural dimensional variations found
in major castings. In particular the width across the appliance recess could be critical.
APPLIANCE WEIGHT (Excludes Packaging)
Model: AGA Dual Control (DC3) - 996lb (452kg)
Hotcupboard - 242lb (110kg)
Data plate located behind plinth.
*NOTE: A 5” CLEARANCE HOLE IS REQUIRED THROUGH COMBUSTIBLE MATERIAL, TO ALLOW 1
1
/2CLEARANCE
AROUND THE FLUE PIPE, (See Fig. 8), Page 15.
A B C D E F G H J K L M N P Q R S T U
mm 1478 951 913 680 1388 760 1145 698 116 10 565 689 43 118 55 634 75 760 330
inch
58
1
/4 37
1
/2 36 26
3
/4 54
5
/8 29
7
/8 45
1
/8 27
1
/2 4
9
/16
3
/8 22
1
/4 27
1
/8 1
3
/4 4
5
/8 2
1
/8
25
3
30 13
OVERHEAD
CUPBOARD