CONNECTION TO THE POWER SUPPLY - AGA DC3
Electric Shock Hazard
Rating plate is located behind removable plinth, see Fig. 4, Page 9
Electrical grounding is required on this appliance.
DO NOT connect to the electrical supply until the appliance is permanently 
grounded.
This appliance must be connected to a grounded metallic permanent 
supply or a grounding connector should be connected to the grounding 
terminal or wire lead on the appliance.
Failure to follow these instructions could result in death or serious injury.
This range must be supplied with a 240V, 60Hz power supply and connected to an individual, 
properly grounded branch circuit protected by a circuit breaker. At 240V, it has a maximum load 
of 30 amps. Electric hook-up must be done by a licensed electrician. This unit must be installed 
according to local codes, or in the absence of local codes, the National Electrical Code for the 
country of installation.
l  Product installation requires a separate (not shared) 240V/40 amp circuit protected by an 
  appropriate branch circuit supply.
l  The service cord on your range is fitted with a standard four (4) prong type 14-50P plug 
    (matching receptacle 14-50R).
The method of connection to the mains electricity supply must facilitate complete electrical 
isolation of the appliance.
The mains connection and isolation should not be positioned above the range and must be 
positioned within the area defined in Fig. 4, Page 9.
THIS RANGE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY 
BEFORE SERVICING. THE RANGE IS DESIGNED FOR THE VOLTAGE STATED ON THE 
RATING PLATE, WHICH IS SITUATED BEHIND THE PLINTH COVER.