Specifications
AGArangeusa.com
AGA IS A MEMBER OF THE MIDDLEBY RESIDENTIAL LUXURY BRAND PORTFOLIO
INSTALLATION
Range Dimensions
When surveying for range installation the actual 
clearance required for the ‘body’ of the appliance 
should be increased by ⅜" beyond the figures quote 
above. This allows safe margin to take into account the 
natural dimensional variations found in major castings. 
In particular the width across the appliance recess 
could be critical.
Range Base or Hearth
It is essential that the base or hearth on which the 
range stands should be level. The base of the built-
in AGA plinth must be level and sit above finished 
floor height for service access. The front plinth cover 
is removable and must not be obstructed by flooring 
or tiles. If necessary the range must be raised by the 
thickness of the tiles to ensure the plinth can be 
removed.
Minimum Clearance to Combustibles
A gap of at least ½" must be observed between 
the rear of the top plate, and the wall behind the 
appliance. If the rear wall is of combustible material 
there must be a gap of 1".
Clearances
A ⅛" gap is required each side between the range top 
plate and adjoining work surfaces that may be fitted, 
this is to allow for the safe removal of the top plate 
should this be required at a later date. Where ranges 
are fitted against side walls a 49/16" side clearance is 
required on the right and left hand side for oven doors 
access. If the AGA is to be installed in a brick recess, 
then the minimum clearance should be increased 
by at least ⅜" , to allow for the walls not being square. 
In addition a minimum clearance of 39½" must be 
available at the front of the range to enable it to be 
serviced.
Range Hoods
It is recommended this AGA is fitted with a range 
hood. The AGA venting system is located on top of 
the AGA between the two hotplates, and is designed 
for venting the moisture from the ovens. The range 
hood should be positioned not less than the minimum 
height as recommended by the manufacturer, from 
the top of the AGA.
39" CLASSIC  
DUAL CONTROL 
ELECTRICGAS