file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm 09/05 EINS 512426 GC 3 (THREE OVEN) Installation Instructions PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. CONTENTS SECTION INSTALLATION BASE OR HEARTH OPEN FLUE RANGE - MODEL GC3 (THREE OVEN) VENT CONNECTION WALL TILING GAS SUPPLY - U.S.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm TECHNICAL SPECIFICATION INSTALLER SERVICING INSTRUCTIONS - GC3 (THREE OVEN) YEARLY SERVICE INSTALLATION NOTE: THESE INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER TO RETAIN FOR FUTURE REFERENCE. Aga Gas Fired ranges are delivered unassembled.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm Fig 1. Open Flue Model GC3 DESN 512843 Fig 2. Section Through Downdraught Diverter A VENT CONNECTION A 100mm (4in) Type B Gas Vent must be used and fastened by screw to the draft hood flue collar. file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm U.S. The gas vent must be connected to a chimney or independently and in accordance with Chapter 26, chimney, Gas Vent and Fireplace Systems of the current issue of Equipment and Volume of the ASHRAE Handbook. The gas vent proximity to combustible materials must be installed as recommended in ANSI/NFPA 211 and according to manufacturers instructions.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm Fig 3. WALL TILING If the cooker is to stand in a recess or against a wall which is to be tiled in no circumstances should the tiles overlap the range top plate. GAS SUPPLY - U.S. PIPE THREADS NOTE: A GAS CONTROL VALVE MUST BE INSTALLED IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT SUPPLIED). 9.5mm (3/8in) N.P.T. Male connection near the front of the range on the LH or RH side. (Optional). ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm Fig. 4 - Model GC3 Open Flue DESN 512430 LOCATION OF NAME PLATE The model and serial numbers for this appliance are found on the data plate. These numbers must be used when requesting advice from your Aga Distributor. The name plate is located on the burner housing panel behind top left door. The maximum gas inlet pressure at the appliance must not exceed 12 inches w.g. (2.98kPa) for Natural Gas and 14 inches w.g. (3.48kPa) for L.P. Gas.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm (See Fig. 8). REPLACEMENT PARTS In the event of component failure, which requires replacement, contact your local Aga Distributor who will advise and supply the necessary replacement. Expendable components that will require replacing at some time or other are listed as follows: 1. 2. 3a. 3b. 4. 5a. 5b. 6. Description Pilot Thermocouple Main Burner Pilot Burner Assembly N.G. Pilot Burner Assembly L.P.G.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm Fig. 5 DESN 512439 Fig. 6 Aga Gas Cooker - All Models DESN 510818 file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm Fig. 7 DESN 512440 Fig. 8 DESN 512431 INSTALLER SERVICING INSTRUCTIONS - GC3 (THREE OVEN) It is recommended that the range be serviced at regular annual intervals. Arrange with the householder that the range has been turned OFF the night before to ensure it is cold upon arrival.
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS512426/EINS512426.htm 1. Isolate the gas supply by turning off the service gas valve beneath the combination gas valve. Break the hexagon union connection nut. (See Fig. 7). 2. Detach inner burner fixing screws (See Fig. 7) and draw complete gas burner assembly clear of the combustion chamber resting it on the floor in front of the range.