User manual
page 24 of 27 Report No. 55S072147/NCH/CZ
IEC 601 + Am. 1& 2
Clause Requirement + Test Result - Remark Verdict
TRF No. I6011__C TRF originator: UL
56.1 TABLE: lists of critical component parts P
Object/part No Manufacturer/
trademark
Type/model Technical data Standard Mark(s) of
conformity
1
)
Enclosure
(for models
GODx7yzMI,
GOKx7yzMI)
Bayer FR2000 Rated V-1 or
better, 1.6 mm
thick min.
UL 746
(Harmonized
with IEC 60707
& IEC 60695-11-
10)
UL
-Alternate Use- Chi Mei PA-765A Rated V-1 or
better, 1.6 mm
thick min.
UL 746
(Harmonized
with IEC 60707
& IEC 60695-11-
10)
UL
-Alternate Use- Various Various
Rated V-1 or
better, 1.6 mm
thick min.
UL 746
(Harmonized
with IEC 60707
& IEC 60695-11-
10)
UL
Enclosure
(for model:
ER-191)
Various Various
Metal,
min. 0.81mm
thick
-
-
AC Inlet Zhang Jia Gang
Hua Feng
HF-301 250Vac, 10A UL 498
VDE 0625
EN 60320
UL, VDE
-Alternate Use- Solteam ST-01 250Vac, 10A UL 498
VDE 0625
EN 60320
UL, VDE
-Alternate Use- Rich Bay R-301SN 250Vac, 10A UL 498
VDE 0625
EN 60320
UL, VDE
Power Switch Solteam MR-21 250Vac 10A UL 1054
VDE 0630
EN 61058
UL, VDE
-Alternate Use- Zhang Jia Gang
Hua Feng
HF-606 250Vac, 12A UL 1054
VDE 0630
EN 61058
UL, VDE
-Alternate Use- Light Country R 19 series 250Vac, 4A UL 1054
VDE 0630
EN 61058
UL, VDE