Getting Started Guide User Manual

Verify that Status displays Connected.3.
Note: If Status displays Not Connected, verify that the EZ−Guide 500 to Rawson controller cable is
securely connected to the EZ−Guide 500 lightbar and the Rawson controller. If the cable is secure, verify
that the EZ−Guide 500 lightbar and Rawson controller are configured correctly, as detailed above.
On−Screen Features with a Rawson Controller
When the Rawson variable rate controller is connected to the lightbar, the following features appear or become
available:
ITEM DESCRIPTION
1 The actual current rate
2 Switching indicator (grey) shows that the controller is in manual switching mode.
3
Boom section status indicators change color to show the current state of each boom section:
* Green − The boom section is enabled and spraying.
* Red − The section is off (the switch is off).
4
Application indicator. The wheel spins when the Rawson master switch is on and the unit is
reporting it is running.
5
36