Getting Started Guide User Manual

EZ−Guide 500 to Rawson controller cable pinouts
The pinouts for the EZ−Guide 500 to Rawson controller cable (PN 69730) is shown below:
TO EZ−GUIDE 500
PINS
TO RAWSON
PINS
2 −−−−−−−−− 2
3 −−−−−−−−− 3
5 −−−−−−−−− 5
[−−−−−− 4
[−−−−−− 6
[−−−−−− 7
Note: Pins 4, 6 and 7 on the Rawson connector must be wired together.
Rawson Controller Setup
To configure the EZ−Guide 500 lightbar to communicate with the Rawson variable rate controller, do the
following:
EZ−Guide 500 lightbar setup
On the EZ−Guide 500 lightbar:
Select Configuration / Application Control / Controller Settings .1.
Press . The Controller Settings screen appears.2.
Change Controller type to Rawson.3.
34