Installation Sheet
T5L Under Cabinet Series Hardwired LED Undercabinet Fixture
Page 1 of 2 8060797
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle an energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in
water.
Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded.
Do not touch LED light engine or heat-sink.
12-inch minimum spacing distance from luminaire
required for all objects located under fixture.
This fixture is to be used for general indoor lighting in dry locations
only.
This fixture is dimmable. The following dimmers are approved for
use to achieve smooth dimming down to 10% of full scale:
Leviton – 6633, 6681, 6621-WWP, 6631-WWP, IPX06-1,
Lutron – TG-600P, TG-603P, AY600P, MACL153MH, SELV-300P,
DVCL-153P,GL600H,SFTU5A3P, S600P, SCL-153PH
Legrand / Pass & Seymour – T600WV, WS700TCCCVG
Cooper – 6013W
Assembly Instructions
1. Preparation for Installation
A. Disconnect electrical power before installing or servicing any part of this fixture.
B. Determine the best location for the fixture, by dry fitting to ensure proper placement.
C. This fixture has been designed to be (Hardwired), depending on your local NEC code power
will need to be brought to the fixture by your electrician with Romex NM-B,BX Cable or
Conduit.
D. Once power has been brought to the fixture location proceed to step 2.
Fig.1
2. Hardwire Installation Preparation
(Skip this step if using Cord to Outlet or Link-to-Fixture Installation to Power Unit)
A. Place fixture on a clean flat surface, remove frosted white Poly carbonate diffuser, disengage cover plate with your thumbs and tilt open .
B. Remove appropriate 3/8” diameter knockout for supply wiring entry.
C. Determine appropriate connector:
i) BX/Romex NM-B Cable connector is included(Ref Fig.2).
Fig. (2)
ii) Flexible conduit BX (AC) 3/8”trade size cable (8) (not
included).
iii) Anti-short bushing (not included Ref Fig 3).
Fig. (3)
D. Insert cable connector (3) into the housing hole opening. Secure it with the nut.
E. Trim away approximately 7: inches of the BX amour (using a BX cutter ( Not include). Push the exposed wires (hot, neutral and ground)
through the anti-short bushing and slide this bushing all the way down the exposed wires, and insert it into the end of the cable, this will
ensure that the wires will not get nicked, as shown in fig ( 3)
F. Follow the directions below for mounting and proceed to Hardware Installation Complete.
Fig 4.