Installation Guide

LED Fixed Rail Luminaires
Surface Mount
120VAC / 60Hz
8061341 R0
Page 1 of 1
Series: CARF, CHRF, CRRF,
GRAF, MTRF, KERF
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially
fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit and can be used in conjunction with most 2-wire, triac dimmers.
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate
ground wire (green) contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry or damp locations only.
Disclaimer
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment
has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005 (B). These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
ASSEMBLY INSTRUCTIONS
Step 1 Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before
installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton.
C. Remove circular gem bar (2) from the fixture base by removing two
screws (3).
Wiring All wiring must take place inside junction box (not included).
Caution: Make sure power is off at fuse or circuit breaker box. Check power
wires for damage or scrapes. If power supply wires are within three inches
of the LED driver, use wire suitable for at least 90°C (194°F).
Note: Most dwellings built before 1985 have supply wire rated to 60°C.
Consult a qualified electrician before installing.
Step 2 Wiring fixture
A. Make all wire connections to appropriate wire. Secure with wire
nuts (provided).
B. Connect the green wire from the fixture to the supply power source
ground wire.
C. Connect the black wire from the fixture to the black (L) wire from
supply power source
D. Connect the white wire from the fixture to the white (N) wire from
supply power source
E. Pull on each wire lead to make sure connections are secure. Make
certain no bare wires are exposed outside of wire connectors. Tuck
all connections neatly into the junction box (5).
Step 3 Mounting
A. Place fixture base (1) over the gem bar, aligning the two mounting
holes on the side and secure with two screws (3).
Step 4 Restore power at fuse or circuit breaker box
Limited Factory Warranty
This fixture is warranted to be free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5
years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not
cover failure due to improper installation, misuse, mishandling or damage incurred in transit.