User's Guide

Table Of Contents
28
Testing in SmartAuto
®
OTDR
An optional launch quality check enables users to detect dirty,
damaged, poorly seated, or mismatched (UPC to APC) connectors.
To perform the launch quality check:
1. With the Launch Quality Check option
A
enabled in the OTDR
or General Settings screen, initiate an OTDR test.
2. The FlexScan will assess the loss and reectance at the OTDR’s
connection to the launch cord (ber ring) or ber under test.
3. If excess loss or reectance is detected, the OTDR displays the
‘Launch Quality is Poor’ warning screen
B
.
From this screen the user may chose to perform one of the
following:
Cancel a test by touching either Cancel
C
or Back
D
.
Clean and reconnect connectors and repeat the launch quality
check by touching Re-check
E
.
Continue testing without checking and cleaning the
connection by pressing Continue
F
.
Note: Testing a ber with poor launch quality may produce
poor test results.
Launch Quality Check
B
A
D
E
C
F