User`s manual

Operation 63
USB-1900 Series
clock frequency. The maximum counting width is 32-bit. Decrease
of the counter value in Edge Separation Measurement mode is
shown.
Figure 4-26: Mode 9-Edge Separation Measurement
4.8.10 Mode 10: PWM Output
The USB-1900 Series timer/counter can also simulate a PWM
(Pulse Width Modulation) output. By setting a varying amount of
Pulse_initial_cnt and Pulse_length_cnt, varying pulse frequencies
(Fpwm) and duty cycles (Dutypwm) can be obtained. PWM output
is shown.
Figure 4-27: Mode 10-PWM Output
Calculation of the PWM frequency and duty cycle is as follows.
1313 12 11 9 8 7 6
S o f t w a r e s t a r t
5432111111
G a t e
C L K
A U X
C o u n t v a l u e
10
T I M E B A S E
P W M O U T
P u l s e _ I n i t i a l _ c n t = 0 x 7 P u l s e _ I e n g t h _ c n t = 0 x B
cntlengthPulsecntinitialPulse
cntlengthPulse
Duty
cntlengthPulsecntinitialPulse
F
F
PWM
Timebase
PWM
____
__
____
+
=
+
=