User`s manual

62 Operation
4.8.7 Mode 7: Single-Triggered Continuous Pulse Generation
This mode is similar to Mode 5 except that the counter generates contin-
uous periodic pulses with programmable pulse interval and pulse-width
following the first active edge of GPTC_GATE. When the first
GPTC_GATE edge triggers the counter, GPTC_GATE has no effect until
software start is executed again. Generation of two pulses with a pulse
delay of four and a pulse-width of three is shown.
Figure 4-24: Mode 7-Single-Triggered Continuous Pulse
4.8.8 Mode 8: Continuous Gated Pulse Generation
This mode generates periodic pulses with programmable pulse interval
and pulse-width following software start. GPTC_GATE enables/disables
calculation. When GPTC_GATE is inactive, the counter halts the current
count value. Generation of two pulses with a pulse delay of four and a
pulse-width of three is shown.
Figure 4-25: Mode 8-Continuous Gated Pulse
4.8.9 Mode 9: Edge Separation Measurement
Measures the time differentiation between two different pulse signals.
The first pulse signal is connected to GPTC_GATE and the second signal
is connected to GPTC_AUX. Clocks that pass between the rising edge
signal of two different pulses through the 40 MHz internal clock or exter-
nal clock are calculated. You can calculate the time period via the known
44 4321021
S o f t w a r e s t a r t
0321021
032
G a t e
C L K
C o u n t v a l u e
O U T
44 3321021
S o f t w a r e s t a r t
0321021
103
G a t e
C L K
C o u n t v a l u e
O U T