User manual
    AFG-2000 Series User Manual 
118 
The modulation source is set to internal. 
SOURce[1]:FM:INTernal:FUNCtion 
Set
Query
Description 
Sets the shape of the modulating waveform from 
sine, square or ramp. The default shape is sine.  
Note 
Square waveforms have a 50% duty cycle. Ramp 
waveforms have a symmetry of 100%. 
Syntax 
SOURce[1]:FM:INTernal:FUNCtion 
{SINusoid|SQUare|RAMP } 
Example 
SOUR1:FM:INT:FUNC SIN 
Sets the FM modulating wave shape to sine.  
Query Syntax 
SOURce[1]:FM:INTernal:FUNCtion? 
Return Parameter 
SIN 
Sine 
SQU 
Square 
RAMP 
Ramp 
Query Example 
SOUR1:FM:INT:FUNC? 
>SIN 
The shape for the modulating waveform is Sine. 
SOURce[1]:FM:INTernal:FREQuency 
Set
Query
Description 
Sets the frequency of the internal modulating 
waveform only. The default frequency is 10Hz.  
Syntax 
SOURce[1]:FM:INTernal:FREQuency 
{<frequency>|MINimum|MAXimum} 
Parameter 
<frequency> 
2 mHz ~ 20 kHz 
Example 
SOUR1:FM:INT:FREQ +1.0000E+02  
Sets the modulating frequency to 100Hz. 
Query Syntax 
SOURce[1]:FM:INTernal:FREQuency? 
[MINimum|MAXimum] 